BTEX Gas Chromatography

PyxisGC BTEX

PyxisGC BTEX is a compact gas chromatograph designed for real-time BTEX monitoring in ambient air, including benzene, toluene, ethylbenzene, and xylenes. By using ambient air as its carrier gas, it helps reduce installation complexity, routine service visits, and long-term operating costs for remote air quality monitoring sites.

Ambilabs PyxisGC BTEX gas chromatograph on tripod in a Colorado field installation

Carrier-Gas-Free BTEX Gas Chromatograph

Built around a high-sensitivity PID detector and compact MEMS-based hardware, PyxisGC BTEX separates and quantifies benzene, toluene, ethylbenzene, and xylenes at ambient concentrations without a traditional carrier gas cylinder.

Automatic analysis, autocheck, and autocalibration keep the system running unattended in the field, with Pollution Guardian cloud software providing remote access to results and diagnostics.

Target Compounds Benzene, toluene, ethylbenzene, and xylenes
Carrier Gas Uses ambient air instead of gas cylinders
Monitoring Type Real-time outdoor BTEX monitoring
PyxisGC BTEX carrier-gas-free gas chromatograph for ambient air monitoring

Designed for ambient monitoring: PyxisGC BTEX supports continuous, unattended BTEX measurement wherever ongoing outdoor air quality data is needed.

Compact BTEX analysis with automatic operation and remote access

PyxisGC BTEX combines high-sensitivity detection, compact hardware, automatic analysis, and cloud-based data tools for field-based environmental monitoring programs.

Detection

PID Detector

A 10.6 eV photoionization source gives the detector a benzene detection limit below 0.2 ppb, well within ambient-level BTEX concentrations.

Footprint

Compact Footprint

The full analyzer fits a 420 mm x 620 mm x 210 mm enclosure while sampling at 250–450 sccm, small enough for shelter or roadside cabinet installs.

Operation

Automatic Analysis

Scheduled autocheck and autocalibration routines run automatically in the field, keeping calibration current without a technician on site.

Software

Pollution Guardian

Connects over Ethernet, Wi-Fi, or 4G with MODBUS TCP integration, so results feed directly into a customer’s existing SCADA or data system.

Field Monitoring
PyxisGC BTEX installed for highway ambient air quality monitoring and BTEX measurement

Built for air quality monitoring networks and remote sites

PyxisGC BTEX can be deployed anywhere continuous, unattended BTEX measurement is needed for an air quality monitoring program.

This carrier-gas-free operation is especially valuable at remote or hard-to-access sites, where cylinder logistics would otherwise drive site-visit frequency.

Common Applications

  • Smart city air quality: Urban monitoring networks, schools, parks, hospitals, and public areas
  • Fence line monitoring: Industrial boundaries, fuel depots, chemical sites, and waste management areas
  • Transportation monitoring: Highways, garages, tunnels, airports, stations, and harbors
  • Research institutions: Automated ambient air BTEX analysis for environmental studies

Lower maintenance requirements for remote BTEX monitoring

PyxisGC BTEX is designed to simplify long-term field deployment by reducing support needs, lowering site visit frequency, and providing remote access to operating data.

No Carrier Gas Cylinders

Ambient air carrier gas operation eliminates the need for routine carrier cylinder replacement.

Compact Field Deployment

Compact size and low power requirements make the system easier to install, relocate, and integrate into monitoring networks.

Continuous Outdoor Use

Rugged IP55 cabinet construction and automatic system checks support remote ambient monitoring applications.

Pollution Guardian cloud software for real-time data management

Pollution Guardian stores analysis data automatically and allows users to view real-time and historical results, create charts and tables, manage the instrument remotely, and receive user-defined alarms.

Data Review

Real-Time and Historical BTEX Data

View current and archived monitoring results remotely to better understand air quality trends and site conditions.

Alerts

User-Defined Alarms and Notifications

Configure data alarms and receive notifications through SMS, email, or smartphone push notifications.

Control

Remote Diagnostics

Support remote instrument review, diagnostics, status checks, and data access without needing to visit the site.

Reporting

Charts, Tables, and Exports

Create visual data summaries and review BTEX trends for project reporting, site review, and environmental analysis.

PyxisGC BTEX technical specifications

Compact, low-power, and designed for continuous outdoor BTEX monitoring applications.

Instrument

  • Dimensions: 420 mm x 620 mm x 210 mm
  • Operating Temperature: -5°C to 50°C
  • Power Input: 12V DC, Max. 2.5A
  • Power Consumption: Max. 25W
  • Cabinet: Rugged IP55 enclosure

Measurement

  • Detector: High-sensitivity PID, 10.6 eV
  • Analyzed Gases: Benzene, toluene, ethylbenzene, xylenes
  • Lower Detection Limit: Less than 0.2 ppb benzene
  • Carrier Gas: Ambient air
  • Sampling Flow Rate: 250–450 sccm

Connectivity

  • Communication: Ethernet, Wi-Fi, 4G
  • Data Storage: 16 GB internal flash memory
  • Control: Local webserver
  • Integration: MODBUS TCP server
  • Cloud: Pollution Guardian IoT service

Ready to add PyxisGC BTEX to your monitoring program?

Contact Ambilabs to discuss deployment options for your monitoring program, or download the product brochure for reference.